Online SDI Meter

Online SDI metre

About Online SDI Meter

"Innovative Water Technologies" are the sole authorised distributor in India for MABAT - Israel make online SDI meters.

SDI 2200

The SDI 2200 (Silt Density Index) fully automatic, multi-channel online analyzers and monitoring systems.

The SDI 2200 designed for continuous, unattended operation in desalination and other water treatment plants.

Ciyara Saaf
Ciyara Saaf

Advantages

  • Fully complies with the ASTM D4189-07
  • CE certified
  • Up to 85 cycles (to complete one paper filter roll) without operator interference
  • Several modes of operation and calculation per channel
  • Three built-in operational modes:
    1. Manual(one-cycle only)
    2. Auto (programmable time interval)
    3. Remote (pre-started selected channel from remote station)
  • Two built-in calculation formulas can be programmed per channel:
    1. "Standard" mode test for low SDI water (less than 5.0, for 15 minutes).
    2. "Auto Time" mode test for high SDI water (greater than 5.0, for 15 minutes).
  • Measurement Time: 1-15 minutes

Technical Data

CABINATE   PPS / IPS3 ( Wall Mounted)
DIMENSIONS (in mm) W 525 D 310 H 1,126
DIMENSIONS (in IN) W 20.6 D 12.2 H 44
WEIGHT 50 [Kg] or 106 [Lb]
WETTED PARTS PP PVC and Nylon 12
SAMPLE LINE
INPUT PRESSURE 2.4 to 6.0 [Bar] or 35 to 80 [Psig]
FLOW RATE 1.5 [L/min]
FILTER PAPER
TYPE Standard Millipore 0.45 micron paper roll
Length of Roll 6 [Meter] or 20 [Ft]
Up to 85 measurements per roll
Utility Specifications
Air Pressure 5.2 to 8.0[Bar] or 80-120 [Psig]
Electrical 110 - 230 [VAC], 4 [Amp] or 24 [VDC]
Slit Density Index Range 0.00 - 99.99
Rated Environmental Conditions: Indoor or under roof
Environmental Protection IP - 53
Max Operating Ambient 50°C
Max Relative Humidity 80%

Options

  • Options analog output (programmable range) per channel for remote control and monitoring purposes.
  • Booster pump - When supply is in low pressure, one booster pump supports all channels.
  • Temperature measurement and compensation (if necessary).

Control System

  • CPU.
  • Color touch screen.
  • Communication
  • RS485
  • RS232

Etherent Communication

  • Communication with plant SCADA system.
  • Transfer and receive data from the plant controller.
  • SDI remote programming (from plant SCADA system).

Analog Output System

Analog isolated output per channel: 0-5 [Volts], 0-20 [mA] and 4-20 [mA]

Digital Output / Input Signal

  • 8 programmable outputs for status indication
  • Analyzer remote enable-disable operation
  • Seperate remote start for each input

Reliability

Uptime > 99.9%
Repeatibility Less than 0.1 SDI units

How To Order SDI 2200

Analyzer format definition: SDI 220 N-A-E-T

N. - Number of channels (1-4)

A. - Number of analog outputs (1-4)

E. - Ethernet communication

T. - Temperature measurememt

Contact our main offices to order

Analyzer format definition: SDI 220 N-A-E-T

E-MAIL

info@mabat-systems.com

WEBSITE

info@mabat-systems.com